2 - The turret or chassis of the machine is not leveled when the aerial part is fully closed.
3 - The basket is overloaded.
4 - The diagram limit has been reached.
5 - The turret of the machine is not leveled when the aerial part is not fully closed.
6 - The diagram limit has been reached due to more than two stabilizers being lifted off the ground while aerial parts are not fully stowed.
7 - Chassis movement has been disabled.
8 - The planarity angle sensor is either disconnected or the cable is broken.
9 - The slew ring angle sensor is disconnected or the wire is broken.
10 - The telescopic boom extension sensor is disconnected or the wire is broken.
11 - The upper boom angle sensor is disconnected or the cable is broken.
12 - The lower boom angle sensor is disconnected or the cable is broken.
13 - The jib angle sensor is disconnected or the wire is broken.
21 - Load cell 1 is disconnected or the cable is broken.
22 - Load cell 2 is disconnected or the cable is broken.
23 - There is a significant discrepancy between slew ring angle sensor 1 and sensor 2.
25 - The slew ring angle sensor has been dismounted.
26 - There is a significant discrepancy between boom extension sensor 1 and sensor 2.
27 - The steel measuring cable of the extension boom is broken.
28 - There is a significant discrepancy between upper boom angle sensor 1 and sensor 2.
29 - There is a significant discrepancy between lower boom angle sensor 1 and sensor 2.
30 - There is a significant discrepancy between jib angle sensor 1 and sensor 2.
34 - There is a significant discrepancy between load cell sensor 1 and sensor 2.
35 - The general pressure sensor is either disconnected or the cable is broken.
43 - The Battery Balancing System (BBS) is disconnected or the cable is broken.
44 - The EMERGENCY RESCUE button has been activated.
45 - The EMERGENCY RESCUE button is faulty (it is recognized as always being pressed).
50 - The CAN-BUS transceiver is faulty.
70 - The CAN-SENS line is disconnected or the cable is broken.
71 - The power supply is low when the electric motor is set to 110V/230V.
72 - The power supply is low when the 24V battery pack is selected.
73 - A warning indicates low voltage in the engine battery (when the engine is OFF) - the BATTERY ICON is displayed.
74 - A warning indicates low voltage in the engine battery (when the engine is ON) - the BATTERY ICON is displayed.
97 - The radio remote control (Scanreco) receiver is disconnected.
105 - The control position is not correctly selected.
106 - Downward movements are disabled due to the basket anti-release feature being active.
107 - The telescopic boom microswitch (emergency controls) is stuck.
108 - The MAN-PRESENT button is faulty (it is recognized as always being pressed).
109 - The pedal footswitch on the basket is stuck.
110 - The machine is locked from Platform Basket Telematics (PBT).
111 - Platform Basket Telematics (PBT) is disconnected.
112 - The diagram limit has been reached.
113 - The Honda proportional accelerator is faulty.
Solid - The cage pin is not correctly inserted and/or interlocked.